Close Mobile Menu
60 Hudson Street (JFK12) Data Center

60 Hudson Street,
10013 New York New York, USA

164000 SQ.F.  

Total Whitespace

60 Hudson Street (JFK12) Data Center | EPY Host

Digital Realty’s data center at 60 Hudson Street is recognized as one of the world's premier colocation and interconnection facilities, serving as a nerve center for international communications. It offers access to global telecommunications networks and Internet backbones through physical connection points. This facility spans multiple floors, providing low-latency connections to over 400 carriers, financial exchanges, and providers of applications, media, content, and software-as-a-service with a single connection. The building, with its 24 stories and 1,800,000 square feet, is outside the 100-year flood plain and situated in seismic Zone 2A. It has a utility power capacity of 3750 kW, UPS power capacity of 950 kW with N-2N redundancy, power density of 80-125 W/sq. ft., DC power capacity of 500 kW, and generator power capacity of 4500 kW with N redundancy. Cooling redundancy is rated at N+1. The roof is made of membrane and reinforced concrete decking with available roof rights. The floor can support loads of up to 125 lbs/sq. ft., and there are diverse conduit entry points for fiber and building access. Security measures include 24x365 manned security, card key, and biometric access control, digital video monitoring and recording, and compliance with SSAE 16 SOC2 standards. Parking is available on-site. The building, originally known as the Western Union Building, was constructed between 1928 and 1930. It stands 371 feet tall and was initially used for telegraph equipment as the headquarters of Western Union, making it a natural choice for its current role as a data center.

  Colocation Services

Full Cabinets

Partial Cabinets

Shared Rackspace

Cages

  Infrastructure and Services

Suits

Build-to-Suit

footprints

Remote Hands

  Data center compliances

DSS PCI Certified

ISO27001 Certified

HIPAA

SOC 2 Type II Certified

SOC 3 Type 2 Certified

NIST 800-53 Certified

Max power/area 0.150 kW/sq.f.
UPS Redundancy N+1
UPS Description: UPS Redundancy: N+1, 2N
Cooling Redundancy N+1
Cooling Description: In Room Cooling Redundancy: N+1
Standby Power Redundancy N+1
Standby Power Description: Power Capacity: 6,000 (N+1) (kW)
security-staff icon

Onsite Security & Technical Staff

cctv icon

CCTV surveillance

padlock with fingerprint

Biometric Access Control

access icon

Card Access Control

Total Whitespace 164000 sq.f.
Total Building Size 1800000 sq.f.
Tenancy Type: Multi-tenant (mixed use)
Construction Type Retrofitted
Roof Access
Building Floors 24
Max Floor Load 125 Lb/sq.f.
Peering networks 149
Network providers 14
Tenants offering colocation 10
Internet Exchange Points 3